The IO752 I/O module is a PROFINET module to connect real-time target machines to external devices.
The IO752 handles the complete data exchange between the connected PROFINET controller and the real-time application. The data exchange is processed via a dual-port memory. The module acts as one PROFINET device exclusively.
This I/O module is ideal for closed-loop controls and hardware-in-the-loop (HIL) simulations using MATLAB® and Simulink®.
The IO752 I/O module is fully compatible with the Simulink® Real-Time™ workflow. The extensive Simulink® Real-Time™ driver blockset offers comprehensive functionality, and firmware updates are easily available, as the Setup driver block downloads microcontroller firmware each time a target application is initialized.
Key Features
- 2x 10BASE-T/100BASE-TX isolated, auto-crossover function Ethernet connectors enable easy network integration
- Compatible with Real-Time Cyclic Protocol (RTC) – Class 1 & Class 2 (unsynchronized), Class 3 (synchronized)
- Isochronous real-time allows fast and synchronous communication at 250 µs
- Simulates all devices from all manufacturers with one network access point and a maximum of two ports
- Convenient device configuration with GSDML import function
- Data modules can be assigned to slots in the block mask similar to slot configurators in PLC programming tools
- Remote controller devices can acyclically read and write records defined in Simulink
- Supports media redundancy and S2 redundancy
- DMA enables fast data exchange on PCI bus