Products search search close

IO970/IO971: RTD (PT100, PT1000) simulation module

RTD simulation module with up to 18 channels of accurate RTD simulation with Simulink® driver blocks

The IO970 and IO971 product series are RTD (Resistance Temperature) simulation board containing up to 6 resistance channels for simulation of PT100 and PT1000 temperature sensors. More channels per module are available upon request.

Intended for temperature simulation with fine resolution, high accuracy and stability.

Features

  • High accuracy and fine resistance control
  • Short and open circuit simulation
  • PT100 or PT1000 options
  • Simple calibration with external DMM

The following variants are available:

I/O module Channels Resistance Form factor

IO970-PT100-6

6

90Ω to 250Ω

PCI

IO970-PT1000-6

6

900Ω to 2500Ω

PCI

IO971-PT100-6

6

90Ω to 250Ω

cPCI

IO971-PT1000-6

6

900Ω to 2500Ω cPCI
 
Physical  
Form factor PCI or cPCI
Power requirements +5V: 1W typical +12V: 1.2W typical -12V: 1.2W typical
PCI Bus 32-bit/33MHz
Connectors 15-Pin male D-Sub for simulation channels (1 per 6 channels) 9-Pin male D-Sub calibration port
Simulation channels  
Configuration 6 channels (more channels per module are available upon request)
Resistance range 90Ω to 250Ω (PT100 option) 900Ω to 2500Ω (PT1000 option)
Resolution < 8mΩ (PT100 option) < 90mΩ (PT1000 option) continuous resolution, no missing settings
Accuracy 0.8%
Maximum power 100mW
Environmental  
Operating temperature 0 to 55°C
Relative humidity 0 to 90%, non-condensing
Electromagnetic interference immunity (EMI) EN61000-6-1:2001
EMC emissions EN55011:1998
Item ID Product Name Components
2A970X IO970-PT100-6
  •  IO970-PT100-6
  • PT100 RTD simulation, 6 channels, 90Ω to 250Ω
  • Driver block library for Simulink® Real-Time™
  • Installation into real-time target machine
2C970X IO970-PT1000-6
  • IO970-PT1000-6
  • PT1000 RTD simulation, 6 channels, 900Ω to 2500Ω
  • Driver block library for Simulink® Real-Time™
  • Installation into real-time target machine
2A971X IO971-PT100-6
  • IO971-PT100-6
  • PT100 RTD simulation, 6 channels, 90Ω to 250Ω
  • Driver block library for Simulink® Real-Time™
  • Installation into real-time target machine
2C971X IO971-PT1000-6
  • IO971-PT1000-6
  • PT1000 RTD simulation, 6 channels, 900Ω to 2500Ω
  • Driver block library for Simulink® Real-Time™
  • Installation into real-time target machine

Key to X in Item ID
Please replace the X with the code number of the specific target machine into which this I/O module shall be installed:

  • 6 = Performance real-time target machine

Pricing information
We don't publish pricing information on our website. Upon request by e-mail or phone we can provide a complete price list covering our entire product portfolio in various currencies. We recommend that you get in touch with us to discuss your specific needs. We can then quickly provide you with a tailored quotation including technical and pricing information.

 

Included in the Delivery

Supported target machines

Resources

Follow Speedgoat LinkedIn